Grouting in Cold Weather: What You Need to Know About ROMEX Joint Mortar
Temperature Limits, Release, Rain Protection, and Storage: An overview of the most important specifications from the technical data sheets.
Product Overview
1-component systems and jointing sand
ROMPOX® - ECOFINE
Application temperature: 5 to 30 °C
Release at 20 °C (can be walked on / fully loadable) 24 hours / 6 days
Rain protection: approx. 24 hours; cover may rest directly on the surface
Storage: not sensitive to frost; protect from sunlight; do not stack pallets
Important note for cold weather: Cold and moisture extend the curing process
ROMPOX® - EASY
Application temperature: 5 to 30 °C
Release at 20 °C (can be walked on / fully loadable): 24 hours / 6 days
Rain protection: approx. 24 hours; cover may rest directly on the surface
Storage: not sensitive to frost; protect from sunlight; do not stack pallets
Important note for cold weather: Cold and moisture extend the curing process
ROMPOX® - JOINTING SAND NP
Application temperature: 5 °C and above
Release at 20 °C (can be walked on / fully loadable) : 24 to 48 hours / after complete drying
Rain protection: not specified
Storage: in a dry place in the originally sealed bag; frost-resistant
Important note for cold weather: Joint sand must be allowed to dry completely once after wetting. Cold and moisture prolong the curing process
2-Component Systems
ROMPOX® - DRAIN
Application temperature: above 0 to 30 °C
Release at 20 °C (can be walked on / fully loadable): 24 hours / 6 days
Rain protection: 12 to 24 hours; do not place a cover directly on the surface
Storage: frost-free and dry
ROMPOX® - D1
Application temperature: 0 to 30 °C
Release at 20 °C (can be walked on / fully loadable) 24 hours / 6 days
Rain protection: 12 to 24 hours; do not place a cover directly on the surface
Storage: Resin and hardener must be kept frost-free; filler must be kept dry
Important note for cold weather: Cold and moisture extend the curing process and increase the risk of white discoloration
ROMPOX® - D2000
Application temperature: 0 to 30 °C
Release at 20 °C (can be walked on / fully loadable) 6 hours / 24 hours
Rain protection: 12 to 24 hours; do not place a cover directly on the surface
Storage: Keep resin and hardener frost-free; keep filler dry
Important note for cold weather: Cold and moisture extend the curing process and increase the risk of white discoloration
ROMPOX® - D3000
Application temperature: 0 to 30 °C
Release at 20 °C (can be walked on / fully loadable) 12 to 24 hours / 3 days
Rain protection: 12 to 24 hours; do not place a cover directly on the surface
Storage: Protect from frost and direct sunlight
Important note for cold weather: Cold temperatures and moisture extend the curing process and increase the risk of white discoloration
ISATEC® - FLEX
System: 2-component special joint mortar, viscoelastic
Application temperature: above 7 to 30 °C
Release at 20 °C (can be walked on / fully loadable) 24 hours / 7 days
Rain protection: 12 to 24 hours; do not place a cover directly on the surface
Storage: frost-free and dry
Important note for cold weather: Cold and moisture extend the curing process and increase the risk of white discoloration
Cement Grout
ROMPOX® 301 CEM-PF
System: Cement grout
Application temperature: 5 to 25 °C
Release at 20 °C (walkable / fully load-bearing): 3 hours / 7 days
Protection from rain: 24 to 48 hours
Storage: on a pallet, in a cool, dry place in the original bag
Important note for cold weather: Protect from drying out, drafts, direct sunlight, and temperatures below 5 °C and above 30 °C; keep moist for 1 to 2 days. Cold and moisture extend the curing process and increase the risk of white discoloration
Temperature and Curing
The application temperature depends on the system. Jointing Sand NP, ECOFINE, and EASY can be applied at temperatures of 5 °C or higher; the 2-component systems DRAIN, D1, D2000, and D3000 can be applied at 0 °C or higher; and ISATEC FLEX can only be applied at temperatures above 7 °C. Cement Grout 301 CEM-PF is designed for temperatures between 5 and 25 °C. The following applies to all products: At low temperatures, the grout will cure slower. The release times listed in the data sheet apply at 20 °C and should be scheduled accordingly later in colder conditions.
Unfavorable weather conditions
The data sheets for ECOFINE, EASY, D1, D2000, Jointing Sand NP, and 301 CEM-PF note that low temperatures and high humidity extend the curing process. For D1, D2000, D3000, and 301 CEM-PF, they also increase the risk of surface discoloration. If necessary, the surface can be heated overnight or immediately before grouting. After grouting, the surface must be protected for at least 24 hours using a suitable covering and heating solution.
Rain Protection
In the event of long-lasting or heavy rain, the freshly grouted surface must be protected. With ECOFINE and EASY, the cover can rest directly on the surface. With DRAIN, D1, D2000, and ISATEC FLEX, the cover must not rest directly on the surface so that air can circulate. Cement grout 301 CEM-PF must be protected from rain for 24 to 48 hours.
Post-treatment of Cement Grout
Setting cement grout 301 CEM-PF must be protected from drying out too quickly, drafts, direct sunlight, and temperatures below 5 °C and above 30 °C. Moist post-treatment for 1 to 2 days will ensure proper curing.
Storage
2-component-systems must be stored in a frost-free location. ECOFINE, EASY, and Jointing Sand NP are frost-resistant; however, ECOFINE and EASY should be protected from direct sunlight. 301 CEM-PF should be stored on a pallet, in a cool, dry place, in its original sealed bag.
Test Area
If you are unsure, we recommend first testing the product on a small area. Always refer to the specifications in the data sheet for the product in question.